DC motor calculation part 4

 Question =  एक 200 volt Shunt motor का armature resistance (Ra) 1.2 Ω है और supply से 10 ampere का current ले रही हैं। यदि field current 1.2 ampere हो तो machine का back emf मालूम करें ?

Solution = is given, 


VL = 200 volt , IL = 10 ampere,  Ish = 1.2 ampere , Ra = 1.2 Ω , 

Back emf formula = Eb = VL - Ia × Ra , 

» Ia = IL + Ish  » 10+1.2 = 11.2 ampere , 

» ( IL = Ia - Ish  , » 11.2 - 1.2 = 10 ampere , is given) 

So , back emf (Eb) = 200 - 11.2 × 1.2        

» 200 - 13.44 » 186.56 volt , answer ✓ 

( VL) Induced emf = voltage drop in armature + Eb = ( Ia × Ra ) + Eb = 13.44 + 186.56  = 200 volt ).